Open the dispenser door and insert the couple with the pressure window facing the pressure sensing pin in the dispenser body.
2
Attach a nozzle
To attach your nozzle to the end of the coupler, hold the couple in place with your thumb, and twist the nozzle clockwise. Tightening by hand is all you need.
It’s very important to not overtighten the nozzle! It just needs to be finger tight.
3
Secure the pressure sensor and nozzle
Close the dispenser door and secure it with the thumbscrew, tightening it clockwise.
4
Insert a material
Remove the caps from both ends of your material’s cartridge and slide the cartridge into the dispenser body so it seats fully onto the coupler.
5
Mount the motor plunger
Gently insert the motor plunger into the top of your material cartridge, aligning the notch on the motor body to the Voltera logo on the dispenser body. Once it bottoms out, twist the motor 90° clockwise to lock it in place.
You now have a fully assembled smart dispenser that is ready to be mounted to NOVA.