Z-min Switch Replacement
Safety first! Before starting any repair, take a moment to review the safety information in your user manual. An online version of the guidelines can also be found here.
Before you begin
This guide will show you how to access and replace the Z-min switch on the V-One. Before beginning this guide you should have been in contact with our support team.
As you work through this guide please reach out to our email [email protected] or through the chat if you run into any issues or have any questions. We are more than happy to assist you virtually with this repair.
When in doubt, reach out!
Estimated Repair Time:
15 minutes
Tools you will need:
2.5mm Hex Key (Allen Key)
Parts you have received from Voltera:
Z-min limit switch PCB
Replace the Z-min switch PCB
Test the new switch
Plug your V-One back into power and connect the USB to your computer. Power on the V-One and open the software. Once the software has loaded, open the console using the ~ key or by pressing alt + c and enter the command M601 S1
. This will let the V-One know it has a new switch.

Reboot the V-One for the switch change to take effect. You can leave the console and software open while rebooting. Once the printer is connected again, manually test the Z-min switch by pressing it with your finger or a pen.

In the console you should see the z-min switch show as TRIGGERED when pressed and open when released.

Repair Complete!
Congratulations, you have successfully swapped the Z-min switch on your V-One!
Please reach back out to our support team through email ([email protected]) or the chat to let them know everything went well or share any photos, details, and feedback.