Substrate Settings

The Substrate tab allows you to configure profile-level hardware behaviors and surface-probing resolutions for your selected substrate material (e.g., FR4, Kapton, PET, or glass). These settings ensure proper material hold-down, safe travel clearances, and accurate bed topography mapping prior to dispensing.

Access these controls by navigating to Settings > SUBSTRATE.

Probe pitch:

The minimum distance between adjacent probe points. This parameter controls the measurement density for generating your height map. A lower probe pitch will take longer, but will compensate better for height variations, allowing you to print at a lower print height (within reason).

Range: 0.1 to 100 mm

Vacuum:

Controls NOVA’s integrated porous vacuum bed fixture. Set to ON to hold down flexible films, thin laminates, or lightweight substrates flat against the table without requiring physical tape or clamps.

Minimum raise height:

This is the Z-axis travel height for moving between features during printing. This value helps ensure that NOVA will avoid any raised features in your design. Both substrate and ink have minimum raise height values — by default, NOVA will choose the largest of the two to be safe.

Range: 0 to 35 mm