Probe Settings
Probe Point Generation Algorithms
NOVA determines where to take surface measurements based on the algorithm selected:
Original: Uses NOVA’s standard grid-based distribution across the bounding area of your features.
Grouped Mesh (Experimental): Intelligently groups adjacent geometries and creates custom boundary hulls, clustering probe points tightly around active traces while skipping empty areas between distant features.


Grouped Mesh Configuration Parameters (Experimental Algorithm)

When Grouped mesh is selected, you can fine-tune point density, boundary shape, and coverage using the following settings:
Parameter
Default
Unit
Description
Probe corner angle
30
Degrees (°)
Determines the minimum corner angle required to place an explicit probe point along feature boundaries. Smaller angles add points to sharper corners for tighter outline tracking.
Hull probe pitch factor
1
Multiplier of probe pitch
Scales the spacing (pitch) between probe points placed along the outer perimeter (convex hull) of grouped features. Lower values increase perimeter point density; higher values spread points farther apart.
Hole size threshold factor
2
Multiplier of pitch diameter
Sets the cutoff size for internal voids or cutouts within a feature group. Open regions larger than this threshold will not be probed, saving calibration time on empty interior substrate areas.
Mesh expand ratio
0
Percent (%)
Expands the outer boundary of the probe hull beyond the physical edges of your features. Use this buffer when dispensing close to substrate edges or when material spreading requires extra clearance.
Simplification ratio
10
Percent (%)
Controls point decimation along relatively straight contours. Higher percentages remove redundant collinear probe points, reducing probing time without sacrificing heightmap fidelity.
When to Use Grouped Mesh
Sparse & Distributed Layouts: When components or traces are separated by wide gaps, avoiding unnecessary probing across empty substrate spans.
Complex Feature Perimeters: When tracing irregular boards, curved edges, or dense routing paths where contour accuracy directly dictates dispensing consistency.
Last updated