Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Planner Settings

Planner Settings

The Planner tab configures how NOVA converts digital geometries (Gerber or SVG artwork) into physical motion toolpaths for dispensing.

Access these controls by navigating to Settings > PLANNER.

Geometry Preprocessing & Cleanup

  • Simplify polygon (ON / OFF) Reduces redundant vertices along polygon edges while preserving overall shape geometry. Smoothing noisy boundary paths eliminates micro-stutters during head travel, leading to more consistent extrusion width.

  • Remove tiny holes (ON / OFF) Automatically ignores micro-voids, apertures, or small negative spaces that fall below the minimum printable feature size of the mounted nozzle. Prevents nozzle stuttering and unwanted local over-deposition.

  • Fill center (collapse to ridge) (ON / OFF) Ensures solid fill areas are fully covered by generating a final centerline collapse pass (ridge line) inside pockets where standard parallel toolpath offsets leave a gap smaller than one trace width.

Path Optimization & Tool Motion

  • Minimize toolpath travel (ON / OFF) Optimizes rapid travel moves between separate paths to calculate the shortest overall non-dispensing travel distance, cutting down total job duration.

  • Optimize polygon order (ON / OFF) Sequences the print order of individual shapes or pads to maintain contiguous travel paths and minimize temperature or time-dependent ink drying across open passes.

  • No-lift relief travel within polygon (ON / OFF) When moving between adjacent infill passes inside the same closed polygon, the dispenser moves across the area without executing a full Z-lift retract.

    • Tip: Keep OFF for low-viscosity or stringy fluids to prevent smearing; turn ON for high-viscosity pastes to significantly decrease print times.

Direction & Segmentation Parameters

Setting

Default

Unit

Description

Traverse direction

IN → OUT

—

Sets the infill direction for closed polygons. IN → OUT starts at the geometric center and spirals outward toward the perimeter; OUT → IN establishes perimeter boundaries first to protect trace edge definition before filling the interior.

Max arc segment length

0

mm

Sets the maximum chord length when linearizing curves and circular arcs. A value of 0 retains default interpolation; specifying a small positive value creates smoother circular toolpaths at the cost of higher G-code/point density.

Minimum straight segment length

0

mm

Sets a threshold below which micro-segments are merged or ignored. Prevents rapid acceleration/deceleration spikes over microscopic line segments that can cause extrusion blobs or pressure drops.

Last updated

Was this helpful?