Probing and Height Mapping
NOVA uses automated surface probing to generate a digital height map of your substrate prior to dispensing. Because additive electronics rely on micron-level standoff distances, height mapping compensates for substrate warpage, thickness variations, and mounting tilts in real time.
1. How Height Mapping Works
Before dispensing begins, the Smart Probe contacts the substrate at multiple discrete coordinates across the print pattern.
NOVA uses these sampled points to construct an interpolated mathematical mesh of the surface. During the dispensing routine, the Smart Dispenser dynamically adjusts its Z-axis position based on this mesh, maintaining a constant dispensing gap across uneven or flexible substrates.
2. Probe Point Generation
NOVA automatically distributes probe points based on your imported design geometries.
Standard Distribution
By default, the software places a balanced grid of points spanning the bounding area of active traces and pads, optimizing for both calibration speed and surface accuracy.
Grouped Mesh Algorithm
When working with sparse layouts—such as isolated pads or long traces separated by wide gaps—standard grid generation may leave critical features unprobed. In this case the Grouped Mesh Algorithm can be used. See Probe Settings for more details.
3. Editing Probe Points Manually
You can fine-tune, add, or prune probe points interactively within the Dispense workflow without re-running the entire routine.
Add a Point: Press
Ctrl+Clickanywhere on the print canvas to place a new probe point.Remove a Point: Press
Shift+Clickon an existing probe point node to delete it.
4. Visualizing and Exporting Height Data
For quality control, substrate inspection, or troubleshooting adhesion issues, you can visualize the surface topology directly or export the raw point cloud.

Viewing the Height Map Overlay
Ensure the NOVA client is in Advanced Mode (
Shift+\).Toggle the heightmap visualizer.
The viewport displays a color gradient overlay representing substrate high points (peaks) and low points (valleys) relative to your reference plane.
Exporting Probe Data
To inspect substrate planarity externally or document fabrication tolerances:
From the heightmap inspection overlay, select Download probe points.
NOVA exports a raw JSON data file containing the sampled coordinate points (, , and measured values).
Best Practices for Reliable Probing
Rigid vs. Flexible Substrates: Ensure flexible films (e.g., Kapton, PET) are completely flat against the vacuum bed or fixture before probing; trapped air pockets underneath will skew the interpolation mesh.
Point Density: For flat rigid substrates (e.g., FR4, glass), fewer points are required. For thermoformed surfaces or uneven 3D-printed beds, increase point density near tight trace geometries.
Clean Probe Tip: Inspect the Smart Probe contact tip before running calibration to ensure no dried ink or debris affects height reading accuracy.