> For the complete documentation index, see [llms.txt](https://docs.voltera.io/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.voltera.io/docs/nova/learn-nova/nova-software/dispense/probing-and-height-mapping.md). Agents can also search and read this documentation through its [MCP server](https://docs.voltera.io/docs/~gitbook/mcp).

# Probing and Height Mapping

NOVA uses automated surface probing to generate a digital height map of your substrate prior to dispensing. Because additive electronics rely on micron-level standoff distances, height mapping compensates for substrate warpage, thickness variations, and mounting tilts in real time.

### 1. How Height Mapping Works

Before dispensing begins, the Smart Probe contacts the substrate at multiple discrete coordinates across the print pattern.

NOVA uses these sampled $$(X, Y, Z)$$ points to construct an interpolated mathematical mesh of the surface. During the dispensing routine, the Smart Dispenser dynamically adjusts its Z-axis position based on this mesh, maintaining a constant dispensing gap across uneven or flexible substrates.

### 2. Probe Point Generation

NOVA automatically distributes probe points based on your imported design geometries.

#### Standard Distribution

By default, the software places a balanced grid of points spanning the bounding area of active traces and pads, optimizing for both calibration speed and surface accuracy.

#### Grouped Mesh Algorithm&#x20;

{% hint style="warning" %}
Grouped Mesh is an experimental algorithm that requires manual parameter tuning for optimal results. Inspect your generated probe points carefully before probing.
{% endhint %}

When working with sparse layouts—such as isolated pads or long traces separated by wide gaps—standard grid generation may leave critical features unprobed. In this case the Grouped Mesh Algorithm can be used. \
\
See [Probe Settings](https://docs.voltera.io/docs/nova/learn-nova/nova-software/nova-settings/probe-settings.md) for more details.&#x20;

### 3. Editing Probe Points Manually

You can fine-tune, add, or prune probe points interactively within the Dispense workflow without re-running the entire routine.

* Add a Point: Press `Ctrl` + `Click` anywhere on the print canvas to place a new probe point.
* Remove a Point: Press `Shift` + `Click` on an existing probe point node to delete it.

{% hint style="info" %}
Adding or removing points preserves all height measurements already recorded by the probe. You only need to run the probe routine on newly placed or modified points.
{% endhint %}

### 4. Visualizing and Exporting Height Data

For quality control, substrate inspection, or troubleshooting adhesion issues, you can visualize the surface topology directly or export the raw point cloud.

<figure><img src="https://3113512132-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYKzrL5Rz2l0ufpEa39Yc%2Fuploads%2FCxVixHWtycP2G7ktOY9Q%2Fimage.png?alt=media&amp;token=bc9c9668-a375-4391-bf90-2619f5bccb2a" alt=""><figcaption></figcaption></figure>

#### Viewing the Height Map Overlay

1. Ensure the NOVA client is in Advanced Mode (`Shift` + `\` ).
2. Toggle the heightmap visualizer.
3. The viewport displays a color gradient overlay representing substrate high points (peaks) and low points (valleys) relative to your reference plane.

#### Exporting Probe Data

To inspect substrate planarity externally or document fabrication tolerances:

* From the heightmap inspection overlay, select **Download probe points**.
* NOVA exports a raw JSON data file containing the sampled coordinate points ($$X$$, $$Y$$, and measured $$Z$$ values).

### Best Practices for Reliable Probing

* Rigid vs. Flexible Substrates: Ensure flexible films (e.g., Kapton, PET) are completely flat against the vacuum bed or fixture before probing; trapped air pockets underneath will skew the interpolation mesh.
* Point Density: For flat rigid substrates (e.g., FR4, glass), fewer points are required. For thermoformed surfaces or uneven 3D-printed beds, increase point density near tight trace geometries.
* Clean Probe Tip: Inspect the Smart Probe contact tip before running calibration to ensure no dried ink or debris affects height reading accuracy.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.voltera.io/docs/nova/learn-nova/nova-software/dispense/probing-and-height-mapping.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.