Automatic Fiducial Alignment

Automatic Three-Point Fiducial Alignment

NOVA includes a dedicated automatic Three-Point Fiducial Alignment routine to precisely match your digital design to physical reference points on the bed.

Requirements & Best Practices:

  • Marker Geometry: Requires three circular fiducials on your board or substrate.

  • Marker Placement: Disperse markers across the board (forming a triangle) rather than along a single line. This ensures optimal calculation of both linear translation (X/Y) and rotational skew.

  • Layer Matching: Ensure fiducial coordinates are identically placed across all exported layer files.

How It Works:

1

Select fiducials

Select 3 highlighted circular features in the pattern preview to use as fiducials.

2

Scan the bed

Next, NOVA moves across the entire bed and captures photos to generate a stitched, high-resolution image. This full-bed scan provides an overview of the build area, and the system automatically attempts to detect your fiducials and align the circuit.

3

Coarse pattern alignment

Before locking any fiducials, drag fiducial 1 to move the pattern, and drag fiducial 2 or 3 to rotate it. With one fiducial locked, drag either unlocked fiducial to rotate around it.

4

Fine fiducial alignment

Zoom in and drag the center dot of an unlocked fiducial to precisely align its outline with the physical fiducial underneath.

5

Auto-center on fiducial (optional):

When a potential fiducial is detected, select Auto-center on fiducial to refine its position. The camera centers on the detected feature and locks its position automatically.